| Customization: | Available |
|---|---|
| Actuator: | Pneumatic |
| Connection Form: | Thread |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Product diameter | DN15-DN300 |
| Control mode | Normally Closed, Normally Open |
| Applicable medium | Water, Gas, Oil corrosive fluid |
| Body material | Brass, Aluminum, PTFE, Cast steel, Stainless steel |
| Power supply voltage | DC12 ~ 220V ,AC24 ~ 380V |
| Medium temperature | -50 ~ (+120, +200) ºC |
| Medium viscosity | less than 50Cst (when required to be customized) |
| Connection type | Flange, Welding, Internal thread (External thread and special interface can be customized or adapter) |
| Protective performance | dustproof, waterproof, anti-explosion. According to working conditions |
| wiring way | wiring seat type; lead type; plug type |
| Material of Oil Seal | NBR or VITON |
| Response Time | 0.05Second |
Working Principle:
| |
An inlet and An outlet: Normally Closed: When the coil is energized, 2 leads to 1, 1 and 3 off. When the coil is powered off, 2 and 1 are closed and 1 leads to 3. Normally open: when the coil is energized, 3 and 1 off, 1 to 2. When the coil is powered off, 3 leads to 1, 1 and 2 off. |
| One in two out: When the coil is energized, 1 leads to 2, 1 and 3 off. When the coil is powered off, 1 and 2 are off and 1 leads to 3. |
|
| Two in one out: When the coil is energized, 2 leads to 1, 3 and 1 off. When the coil is broken, 2 and 1 are closed and 3 leads to 1. |